Anaesthetic Machines - O'Neill Medicalia Ltd.

Go to content
Anaesthetic Machines
WALL-MOUNTED & PORTABLE ANAESTHETIC MACHINE
PORTANOVA

Suitable for all RCVS accredited core, General Practices & Veterinary Hospitals. (Tiers 1,2 & 3)

 RCVS Practice Standards, April 2014, item 5.7 GP/SA Tiers 2 & 3: “There must be a source of oxygen and emergency oxygen flush with reducing valve, rotameter and vaporiser”.
Portanova Premium

Portanova with accessories
Portanova Legacy version
All of the machines we manufacture are ready for use with OXYGEN CONCENTRATORS

The all-new PORTANOVA Premium compact wall-mounted Anaesthetic Machine, complete with integrated Selectatec mounting position, can accommodate all types of Selectatec Vaporizer, and is one the smallest full-feature Anaesthetic machines in the world. They may be simply lifted off the mounting bracket for use as a portable workstation. The optional Isomiser circle absorber fits directly onto the fresh-gas outlet, without need for spacers or stand-off connectors. The Selectatec mount allows for very rapid fitting and removal of Vaporizers and can reduce the number of Vaporizers required in a Veterinary Practice. Height 35Cm: width 30cm; depth (including Vaporizer) 21cm.These machines are designed specifically for the Veterinary Profession. They are all fitted with high-accuracy Rotameter type Flowmeter, RCVS Compliant, which has flow range optimised for general veterinary use. I.E., Oxygen, range 0.1 to 6 Litres per minute, with the bottom 60% of the tube indicating flow in the range of 0.1 to 2 Litres. This greatly increases the resolution at lower flow rates, facilitating precise flow-settings. Similarly, the Nitrous-Oxide flow range is chosen to suit anticipated usage. Some of our competitors only offer Ball-type flowmeters which do not satisfy RCVS Practice Standards for Approved General practices or Hospitals / Tiers 2 & 3. A Rotameter has a rotating fluted bobbin indicating the rate of flow of gas. The rotation confirms that the gas is actually flowing, as a non-rotating bobbin, or ball, may be held anywhere in a tube by static electrical charge, thereby giving a false indication of flow! A flowmeter using a ball to indicate flow is not a Rotameter! All machines are supplied with a corner Fresh-Gas-Outlet, with integral Emergency Oxygen Flush. Choice of work-tray colour, yellow or blue. Other colours may be offered to match theatre décor, at extra cost. 1 year unconditional warranty on machines and Vaporizers. Legacy models are designed to accept Cagemount vaporizers. It may be used with a Selectatec vaporizer, if a Selectatec Compatibility block is fitted. Oxygen hose with BS Probe, 1, 2 or 3 Metres, £30.

Prices do not include Vaporizers, which are optional extras. Wide range available from stock.  
 
 
Prices: Oxygen-only model £545; Oxygen & Nitrous Oxide £645; O2 Legacy £430; O2 + N2O Legacy £510
WALL-MOUNTED ANAESTHETIC MACHINE
MICRONOVA

Suitable for all RCCVS accredited core, General Practices & Veterinary Hospitals. (Tiers 1,2 & 3)

Micronova with accessories
Micronova two-gas version
Micronova MK2 premium with  Integral Selectatec
All of the machines we manufacture are ready for use with OXYGEN CONCENTRATORS

MICRONOVA WALL-MOUNTED ANAESTHETIC MACHINE.

100% Compatible with Isomiser Circle-Absorber, & Humphrey ADE system.

The all-new MICRONOVA compact wall-mounted machines, complete with integrated Selectatec mounting position, can accommodate all types of Selectatec Vaporizer, and are probably the smallest full-feature Anaesthetic machines in the world. The optional Isomiser circle absorber fits directly onto the fresh-gas outlet, without need for spacers or stand-off connectors. The Selectatec mount allows for very rapid fitting and removal of Vaporizers, and can reduce the number of Vaporizers required in a Veterinary Practice. Height 30Cm: width 30cm; depth (including Vaporizer) 21cm.

Micronova now shares the same wall-mounting bracket as the Portanova. These machines are designed specifically for the Veterinary Profession. They are all fitted with high-accuracy Rotameter type Flowmeter, RCVS Compliant, which has flow range optimised for general veterinary use. I.E., Oxygen, range 0.1 to 8 Litres per minute, with the bottom 60% of the tube indicating flow in the range of 0.1 to 2 Litres. This greatly increases the resolution at lower flow rates, facilitating precise flow-settings. Similarly, the Nitrous-Oxide flow range is chosen to suit anticipated usage. Some of our competitors only offer Ball-type flowmeters which do not satisfy RCVS Practice Standards for Approved General practices or Hospitals / Tiers 2 & 3. A Rotameter has a rotating fluted bobbin indicating the rate of flow of gas. The rotation confirms that the gas is actually flowing, as a non-rotating bobbin, or ball, may be held anywhere in a tube by static electrical charge, thereby giving a false indication of flow! A flowmeter using a ball to indicate flow is not a Rotameter! All machines are supplied with a corner Fresh-Gas-Outlet, with integral Emergency Oxygen Flush.

1 year unconditional warranty on machines and Vaporizers. Legacy models are designed to accept Cagemount vaporizers. It may be used with a Selectatec vaporizer, if a Selectatec Compatibility block is fitted.

Prices: Oxygen-only model £545; Oxygen & Nitrous Oxide £645; O2 Legacy £410; O2 + N2O Legacy ££510.
Prices do not include Vaporizers, which are optional extras. Wide range available from stock.   

Prices: Oxygen-only model £475; Oxygen & Nitrous Oxide £575.
Legacy Cagemount models; Oxygen or N2O pipeline, with BS Probe, 1, 2 OR 3 Metres long, £30
ANAESTHETIC MACHINES FOR SIZE 'F' CYLINDERS
ECONOVA RANGE

These simple, compact and robust anaesthetic machines are generally used for single-gas anaesthesia. They are designed to securely hold two 'F' size oxygen cylinders, one in use, one in reserve. British-made Bull-nose reducing valve. Low centre of gravity, combined with high quality castors for easy and safe mobility. Robust steel frame: chip and solvent resistant white finish. All 3 models now have a monitoring shelf / instrument tray on top. Truly compact dimensions: width 42cm; depth 42 cm; height 146cm.

The Economy model is designed to accept the main legacy Vaporizer configurations, Cagemount tapers, and also Selectatec in conjunction with Selectatec Compatibility mounting block. These machines are supplied with a corner Fresh-Gas-Outlet. Inlet and outlet connections for Cagemount Vaporizer, or optional Selectatec quick-fit / release Vaporizer mounting £135.
Prices do not include Vaporizers, which are optional extras. Wide range available from stock.

The PREMIUM MODEL is our all-new machine, complete with integrated Selectatec mounting position, can accommodate all types of Selectatec Vaporizer. Machine features right-angled fresh-gas outlet, with integral emergency oxygen flush (RCVS compliant). The high-accuracy Oxygen Rotameter has a flow range especially suitable for general veterinary use, i.e. 0.1 to 8 Litres per minute, with the bottom half of the tube indicating flow in the range of 0.1 to 2 Litres. This greatly increases the resolution at lower flow rates. The optional Iso-miser circle absorber fits directly onto the fresh-gas outlet, without need for spacers or stand-off connectors. The Selectatec mount allows for very rapid fitting and removal of Vaporizers, and can reduce the number of Vaporizers required in a Veterinary Practice. It is also very useful when Sevoflurane is being introduced to a practice.

Suitable for Core (Tier 1), General Practices (Tier 2), & Veterinary Hospitals (Tier 3) RCVS Accredited Practices.

The ECONOMY MODEL comes complete with: top-quality British-made Bull-Nose pressure reducing valve; cylinder key; 0 to 5 Litres-per-minute therapy type ball flow-meter; transfer tubing, with Vaporizer inlet adaptor; right-angled fresh-gas outlet. Suitable for Core (Tier 1) RCVS Accredited Practices.

Both models are suitable for use with OXYGEN CONCENTRATORS
               
Economy Model £520.           Premium Model £835               Premium Model with
               (Core / Tier 1)                         (Tiers 1, 2 & 3)                Oxygen Concentrator £1585

ANAESTHETIC MACHINES FOR SIZE 'E' CYLINDERS OR PIPED GAS
 
SUPERNOVA RANGE

Suitable for all RCVS accredited Core, General Practices, & Veterinary Hospitals. (Tiers 1, 2 &3)

SUPERNOVA RANGE.

All-new machines designed specifically for the Veterinary Profession. Available in Pin-Index 'E' size cylinder configuration, all-pipeline, or a combination of both. Future-proof design permits simple conversion of cylinder-type machine to pipeline model, or for use with OXYGEN CONCENTRATORS should user requirements change.
 
SELECTATEC mounting block is included as standard on all of our SUPERNOVA machines. Our competitors charge an extra £199 for this valuable feature! High accuracy 9" Rotameter type flow-meter has a flow range suitable for general Veterinary use, i.e. 0 – 8 Litres-per-minute Oxygen, with the bottom half of the tube indicating flow in the range of 0.1 to 2 Litres. This greatly increases the resolution at lower flow rates, facilitating precise control of gases. This is particularly valuable when using Low-Flow techniques, or a Circle-Absorber. Combined fresh-gas outlet and emergency Oxygen flush. Shelf for multiparameter monitoring units. 75mm diameter quality castors for easy manoeuvrability. Robust steel frame: chip and solvent resistant white finish: compact dimensions. Bright yellow, easy-clean work surface. 1 Year warranty.

Tell us what combination of O2 and N2O cylinders, and/or piped gases you would like, and we can build it for you!

Prices do not include Vaporizers, which are optional extras. Wide range available from stock.

SUPERNOVA    OXYGEN - ONLY MACHINES
Cylinder model; 2 x Oxygen Pin–Index, £1,145.
Piped–gas model; Oxygen pipeline, + 1 X Oxygen Pin-Index, suitable for use with Oxygen Concentrator. £1,045.
Piped–gas model; Oxygen pipeline, + 1 X Oxygen Pin-Index + Oxygen Concentrator £1690.
Piped gas model; Oxygen pipeline only. Suitable for use with Oxygen Concentrator. £845.
Piped gas model; Oxygen pipeline only, + Oxygen Concentrator. £1590

SUPERNOVA    OXYGEN + NITROUS OXIDE MACHINES
Cylinder Model:   1X O2 Pin-Index, 1 x N2O, £1,245.
2-gas cylinder/piped-gas combinations, P.O.A.
DIMENSIONS: 2 Cylinder machine – width 50 Cm; depth 48 Cm; height 129 Cm      
         
About Us

O'Neill Medicalia has over 35 years experience of
servicing all types of veterinary equipment. We
offer a comprehensive equipment management
and servicing programme for anaesthetic machines
and vaprozers.

We routinely issue certification, free of charge, to
satisfy the requirements of the 2010 RCVS practice
standards, as well as insurers, health & safety
agencies etc.

Our Location

10 Percy Street
Liverpool
L8 7LU

0151 708 5268

trade@medicalia.co.uk


Business Hours

Our support team are always more than
happy to assist you. Our Office opening
times are as follows:

Monday-Friday: 9:00am to 17:00pm
Saturday: Closed
Sunday: Closed


Back to content