|
|
|
PATIENT
CIRCUITS |
| |
 |
MODIFIED
AYRES T-PIECE (paediatric version)
The circuit of
choice for smaller animal anaesthesia. It
has been designed to overcome the difficulty of effectively
scavenging waste gas, which has been a
problem with the standard Ayres T-piece. Complete with
500ml closed tail reservoir bag and APL (Adjustable
Pressure Limiting) valve with 30mm scavenging port. It
has a fixed secondary pressure blow-off, set at 28cm
water.
Fresh-gas flow rate 2
-2.5 times patient minute volume. Patient weight up to
7Kg.
Order
PC-2122 Price £20 |
| |
|
 |
AYRES
T-PIECE
Classic
non-re-breathing circuit for cats or small dogs, up to
about 7Kg. Features low resistance and dead- space.
Complete with 500ml open-tail reservoir bag. Fresh-gas
flow rate should be 2-2.5 times patient minute volume.
Order PC-2120
Price £16 |
| |
|
 |
MINI
AYRES T-PIECE
Ideal for
pups, kittens or birds. Similar to basic Ayres T-piece,
this circuit has extremely low dead space. Supplied with Portex 8.5mm mini-link endotracheal connector.
Complete with 500ml open-tail reservoir bag. Fresh-gas
flow rate should be 2-2.5 times patient minute volume.
Order PC-2125 Price £15 |
| |
|
 |
BAIN
CO-AXIAL CIRCUIT
The very
popular Bain Co-Axial circuit features fresh-gas flow
via its small bore central tube, whilst expired gas
travels by the wide bore tube to the re-breathing bag
and APL / scavenging valve. This is an ideal system for
dental or head and neck surgery as there are no valves
at the patient end of the system. Fresh-gas flow rate
should be 2-2.5 times patient minute volume. The patient
should be 10Kg or above.
Order PC-2115 Price £20 |
| |
|
 |
PARALLEL LACK
CIRCUIT
This non
re-breathing system is a modified version of the Lack co-axial
system. Comes complete with
2 Litre re-breathing bag and APL / scavenging valve. 22mm
diameter lightweight tubes ensure a smooth unrestricted
gas flow. No directional flow valves are employed in this
system and it runs at 1-1.5 times the normal patient
volume. Patients should be 10Kg or above.
Order PC-2106 Price £20 |
| |
|
 |
MAGILL
PATIENT CIRCUIT
The ever
popular Magill system comes complete with re-breathing
bag and APL / scavenging valve. Circuit is lightweight,
easy to use, suitable for small patients and can be used
with Nitrous Oxide. Fresh-gas flow rates 1-1.5 times
patient minute volume makes this an economical system.
Patient should be 10Kg or above.
Order PC-2105
Price £20 |
| |
|
 |
ANAESTHETIC
CIRCLE SYSTEM
Basic breathing system with compact parallel Y-piece for
use with Circle Absorbers. Suitable for use with small
animals and colts.
Order PC-2000
Price £12 |
| |
|
 |
UNICIRCLE
Unique co-axial
circuit for use with Circle-Absorbers. All the
advantages of the BAINS circuit, with the economy of the
CIRCLE-ABSORBER. Particularly suited for use with CASCA
(Circle Absorber System for Companion Animals) Very low
resistance to flow. Expired gases in outer tube heat up
the incoming gases in the inner tube, improving humidity
and conserving body heat. Neat, streamlined, tube within
tube design reduces clutter at patient end of circuit.
Order PC-Unicircle.
Price £20 |
| |
|
 |
DIRECT
SYSTEM
A Direct Gas
Delivery System with minimal dead-space at the
patient connection, reducing re-breathing to a minimum.
1 litre reservoir bag. Patients up to 7Kg. Fresh gas
flow 2-2.5 times patient minute volume.
Order PC-2123
Price £20 |
|
|
|
Scavenging Tubing , Order PC-Scavenging. Price per
Metre |
£2.00 |
|
Scavenging Tubing Adaptor 22mm Male to 30mm Female,
Order PC-22M/30F.
Fits APL scavenging port. |
£2.00 |
|
Scavenging Tubing Adaptor 22mm Male to 22mm Female,
Order PC-22M/22F |
£1.50 |
|
Scavenging Tubing Adaptor 22mm Male to 30mm Male,
Order PC-22M/30M |
£2.00 |
|
|
| |
|
 |
WATER
TO-AND-FRO CIRCUIT
Complete
circuit, including Adjustable Pressure Valve, with 22mm
scavenging connection and 2 Metres scavenging tubing,
16oz [450 g] soda-lime canister, 2 litre bag and Portex
swivel connector. Suggested patient weight: over 10kg.
Order PC-Waters. Price £255 |
| |
|
CASCA®
Circle
Absorber System for Companion Animals
The
combination of high fluid-dynamic efficiency, in-line
directional valves, low resistance to flow, integrated
unit design and compact dimensions enables, CASCA to be
used across an exceptionally wide range of patient
body-weights. In circle mode, the range is from 4KG
to 115KG, offering potentially very substantial
reduction in anaesthetic agent consumption. With the
increasing use of Isoflurane, this efficiency takes on
even greater significance. Unit includes a combined
scavenging port and airway pressure limiting valve [A.P.L.],
which contains a unique, patented, back-pressure
device which ensures that the reservoir bag is lightly
extended. This eliminates the need for constantly
"fiddling" with the A.P.L. valve. CASCA is supplied
complete with 1 x Unicircle which is the ideal circuit
for this unit; 1kg of Spherasorb low-dust soda lime; 1
x universal mounting bracket, which helps you mount
CASCA onto any anaesthetic machine.
Order PC-Casca. Price £495 |
|
| |
|
ACTIVENT®
Low-cost Active pollution scavenging system, with built-in
Air-Break.
The
RCVS Practice Standards section 5.12 paragraph 4 states:
"If a sophisticated
active scavenging system is in operation, it must be
serviced annually. A test certificate must be available
and is an acceptable alternative to personal dosimetry."
Activent is a
fan-driven, single-station
anaesthetic pollution exhaust system, usually
wall-mounted. Unlike Fluosorbers (which are bacterial
hazards), Activent will remove
all
anaesthetic waste gases, including Nitrous Oxide. It is
normally wall-mounted,
adjacent to an Anaesthetic work-station. The design
incorporates a fixed 3-Litre reservoir, with one end open
to atmosphere via a safety inlet filter on top of the
unit. This built-in AIR-BREAK
acts as a safeguard against any possibility of the system
generating a positive or negative pressure at the patient
end. The filter is easily removed for cleaning. Activent
draws between 5 and 15 Litres per minute of room air, into
which the waste gas is very simply directed via standard
30mm connectors and 22mm flexible scavenging tubing
(supplied). The air and waste-gas mixture is actively
propelled to the point of disposal,
up to a distance of 15 Metres.
Flow-rate is adjustable to suit local installation
conditions. Push-button "ON/OFF" control with Power "ON"
indicator. A green L.E.D. illuminates to indicate when the
fan is running, as the unit is near silent in operation.
Easily installed using the
Starter Kit (included in
price). Easily connected to the patient-breathing-circuit
APL / exhaust valve, using scavenging tubing & 22mm/30mm
connector (supplied).
Activent can pay for itself
in 12 months!!
E.G. 12 x Fluosorber @ £24 each = £288
Included in the
price:
30-22mm connector with 2 Metres
scavenging tubing,
connects patient-circuit scavenging (APL) valve to
Activent; ‘V’ plate & bracket
wall-mounting kit;
The A.C. to (adjustable) D.C.
Power Supply Unit:
Installation Starter Kit, this is sufficient to
take the waste gases up from the Activent, into a right
angled connector, through a wall (22mm diameter hole) to
the exterior of a building, terminating in a ‘tee-piece’.
Customer may extend this system, to a maximum length of 15
Metres, using standard domestic 21.5 mm overflow tubing
and connectors, readily and cheaply available from B&Q,
Plumb-Centre, and most D.I.Y. stores.
Price £265
- N.A.T.O. Order Code: 6515-99-547-8183 |
|
| |
|
|
SPHERASORB, Soda Lime.
Low dust, low flow
resistance. Pink to white.
Spherasorb is made of 3-4mm smooth-surfaced spheres,
processed to minimise potential dusting. Its uniform shape
allows consistent bed packing, resulting in a more even
flow of anaesthetic gases, with less resistance to flow,
through the absorber.
Order PC-2174
5Kg Soda Lime in plastic dispenser. Price £24.00
Order PC-2172
1Kg Soda Lime in plastic bags. Price £ 4.80 |
 |
| |
|
|
|
Home
Services
Contact Details
Ex-NHS Equipment
Weighing Scales
F-size Cylinders E-size Cylinders Scavenging/Pollution
Portable/Wall Mounted
Piped Gas Installation
Vaporizers
Patient
Circuits Autoclaves
Monitors
|
|
|